AC OUTPUT |
|
Output voltage: |
120 VAC true sinewave std, up to 600 VAC optional |
|
Output rating: UPS |
3000 VA
0.65-0.75 pf std, optional configurations to 18,000 VA |
|
Non-linear load capacity: |
Up to 100% non-linear load capability w/o derating |
|
Output voltage regulation: UPS |
± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step) |
|
Overload surge capacity: |
110% for 10 minutes; 125% for 30 seconds |
|
Harmonic distortion: |
Less than 5.0% into 100% non-linear load |
|
Output frequency: UPS |
60 or 50 Hz ± 2.5% synchronized to utility
60 or 50 Hz ± 1.0% w/ utility not available |
|
Operational status |
Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off |
|
AC INPUT |
|
Input voltage selection: |
120 VAC, optional up to 600 VAC, up to 440 Hz |
|
Input voltage tolerance: UPS |
+15% -25% of nominal input rating |
|
Input/output isolation: |
Up to 120 dB electrical noise attenuation |
|
Input transient suppression: |
Complies with IEEE 587 and UL 1449 |
|
Input control/protection: |
Guarded 2 pole switch w/ fuse, optional breaker
Guarded cold start to turn on w/o AC present |
|
Input power connection: |
AMP CPC Type XII locking, various options |
|
BATTERY |
|
Type: |
Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+) |
|
Battery life: |
Rated for continuous service life of 5 years |
|
DC protection: |
Front panel mounted fuse, optional breaker |
|
Battery expansion: |
Up to 24 hours w/ Battery Expansion Modules |
|
DISTRIBUTION PANEL |
|
Output circuits: |
One output standard, up to eight optional |
|
Output control: |
Optional panel switches or breakers
Optional remote interlock ON/OFF control |
|
Output receptacles: |
MS locking std, various options |
|
MECHANICAL |
|
Dimensions ( H x D x W ): |
36 x 16 x 30 in (914 x 406 x 762 mm) |
|
Alternate Mounting Options: |
Table, Wall, Floor, Portable, Horizontal/Vertical |
|
Shipping weight: |
215 lb. (98 kg) with lift handles front and rear |
|
Audible noise: |
Less than 47 dB @ 5.0 ft., ANSI "A" scale |
|
Cooling type: |
High capacity, positive pressure, forced air |
|
Cooling air direction: |
Side intake, exhaust to opposite side |
|
Air intake filter: |
Washable filter media, various porosities |
|
ENVIRONMENTAL |
|
Storage temperature: |
-13° to 131° F ambient (-25° to 55° C ) |
|
Operating temperature: |
32° to 113° F ambient (0° to 45° C ),higher optional |
|
Operating humidity: |
0 to 95% relative humidity (non-condensing) |
|
Operating elevation: |
Up to 10,000 ft (3,048 m), higher optionally |
|
STANDARDS |
|
United States: |
Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical |
|
Canada: |
CSA C22.2 No. 107 UPS safety requirements |
|
EMI Protection: |
EMI/RFI FCC, Class A, optional MIL STD 461 |
|
OPTIONAL ACCESSORIES |
|
|
Dual Source Input, Batteryless Operation,
Battery Expansion Unit, Automatic Battery Test,
Power Distribution Units, Software Interface |